Search results

Search for "mechanical vibrations" in Full Text gives 13 result(s) in Beilstein Journal of Nanotechnology.

Frequency-dependent nanomechanical profiling for medical diagnosis

  • Santiago D. Solares and
  • Alexander X. Cartagena-Rivera

Beilstein J. Nanotechnol. 2022, 13, 1483–1489, doi:10.3762/bjnano.13.122

Graphical Abstract
  • would be extremely beneficial. This would allow, for example, for the tailoring of artificial tissues to the type of stimuli associated with specific types of activities, such as job-related mechanical vibrations at different frequencies, sports-related accelerations, and other ergonomic factors
PDF
Album
Perspective
Published 09 Dec 2022

A cantilever-based, ultrahigh-vacuum, low-temperature scanning probe instrument for multidimensional scanning force microscopy

  • Hao Liu,
  • Zuned Ahmed,
  • Sasa Vranjkovic,
  • Manfred Parschau,
  • Andrada-Oana Mandru and
  • Hans J. Hug

Beilstein J. Nanotechnol. 2022, 13, 1120–1140, doi:10.3762/bjnano.13.95

Graphical Abstract
PDF
Album
Full Research Paper
Published 11 Oct 2022

Impact of electron–phonon coupling on electron transport through T-shaped arrangements of quantum dots in the Kondo regime

  • Patryk Florków and
  • Stanisław Lipiński

Beilstein J. Nanotechnol. 2021, 12, 1209–1225, doi:10.3762/bjnano.12.89

Graphical Abstract
  • resonances can occur simultaneously [32][33]. Recently, there is also an increasing interest in nanoelectromechanical systems (NEMS) integrating electrical and mechanical functionalities [34][35][36][37][38]. Nanoelectromechanical systems utilizing localized mechanical vibrations have found applications in
PDF
Album
Full Research Paper
Published 12 Nov 2021

Determining amplitude and tilt of a lateral force microscopy sensor

  • Oliver Gretz,
  • Alfred J. Weymouth,
  • Thomas Holzmann,
  • Korbinian Pürckhauer and
  • Franz J. Giessibl

Beilstein J. Nanotechnol. 2021, 12, 517–524, doi:10.3762/bjnano.12.42

Graphical Abstract
  • energy to excite the sensor is very small and mechanical vibrations can dominate the excitation [19]. For low-temperature LFM, the lattice of the substrate can be used to calibrate the amplitude if the periodicity of the lateral features is known [20]. For electrically excited piezoelectric-based sensors
PDF
Album
Supp Info
Full Research Paper
Published 01 Jun 2021

Imaging and milling resolution of light ion beams from helium ion microscopy and FIBs driven by liquid metal alloy ion sources

  • Nico Klingner,
  • Gregor Hlawacek,
  • Paul Mazarov,
  • Wolfgang Pilz,
  • Fabian Meyer and
  • Lothar Bischoff

Beilstein J. Nanotechnol. 2020, 11, 1742–1749, doi:10.3762/bjnano.11.156

Graphical Abstract
  • the neglected ion beam stability, mechanical vibrations, drift, or electromagnetic fields during realistic long-term milling processes for light ions due to the small sputter yield (0.12 for 30 keV He in Au [34]). Additionally, large fluences, necessary for deep milling, often cannot be applied when
PDF
Album
Full Research Paper
Published 18 Nov 2020

An atomic force microscope integrated with a helium ion microscope for correlative nanoscale characterization

  • Santiago H. Andany,
  • Gregor Hlawacek,
  • Stefan Hummel,
  • Charlène Brillard,
  • Mustafa Kangül and
  • Georg E. Fantner

Beilstein J. Nanotechnol. 2020, 11, 1272–1279, doi:10.3762/bjnano.11.111

Graphical Abstract
  • are 17.8 × 17.8 µm and 16.6 × 16.6 µm, respectively, and each is 512 × 512 pixels). An additional 2-dimensional FFT filtering was applied to correct for the main mechanical vibrations in the two original images. The AFM image in Figure 3d is obtained in ORT at 2 kHz tapping rate, 600 nm amplitude and
PDF
Album
Full Research Paper
Published 26 Aug 2020

Multilayer capsules made of weak polyelectrolytes: a review on the preparation, functionalization and applications in drug delivery

  • Varsha Sharma and
  • Anandhakumar Sundaramurthy

Beilstein J. Nanotechnol. 2020, 11, 508–532, doi:10.3762/bjnano.11.41

Graphical Abstract
  • of magnetic NPs (e.g., iron oxide and cobalt oxide NPs) into capsules allows them to respond to magnetic stimuli and produce heat due to magnetic energy dissipation, mechanical vibrations and motion induced in the film, thus releasing the cargo [80]. The Fe2O4-PAH capsules studied with A549 cancer
PDF
Album
Review
Published 27 Mar 2020

Nanomechanical humidity detection through porous alumina cantilevers

  • Olga Boytsova,
  • Alexey Klimenko,
  • Vasiliy Lebedev,
  • Alexey Lukashin and
  • Andrey Eliseev

Beilstein J. Nanotechnol. 2015, 6, 1332–1337, doi:10.3762/bjnano.6.137

Graphical Abstract
  • array. Experimentally we established the excitation of mechanical vibrations perpendicular to the cantilever surface as torsion. The thickness of cantilever arrays influences on stiffness and may also cause an increasing in resonance frequency: from 500 kHz for 2 μm thick cantilevers to 670 kHz for 30
PDF
Album
Full Research Paper
Published 16 Jun 2015

Optimal geometry for a quartz multipurpose SPM sensor

  • Julian Stirling

Beilstein J. Nanotechnol. 2013, 4, 370–376, doi:10.3762/bjnano.4.43

Graphical Abstract
  • ; mechanical vibrations; scanning probe microscopy; scanning tunnelling microscopy; Introduction The heart of any scanning probe microscope (SPM) is its sensory probe. For a scanning tunnelling microscope (STM) this is simply an electrically conducting wire with an atomically sharp apex. For atomic force
PDF
Album
Supp Info
Full Research Paper
Published 17 Jun 2013

Thermal noise limit for ultra-high vacuum noncontact atomic force microscopy

  • Jannis Lübbe,
  • Matthias Temmen,
  • Sebastian Rode,
  • Philipp Rahe,
  • Angelika Kühnle and
  • Michael Reichling

Beilstein J. Nanotechnol. 2013, 4, 32–44, doi:10.3762/bjnano.4.4

Graphical Abstract
  • calculation by using approximations for the demodulator bandwidth is presented in Section 4 of Supporting Information File 1. Experimental Noise measurements are performed with three NC-AFM systems, named systems A, B and C in the following. All systems are well decoupled from mechanical vibrations by spring
PDF
Album
Supp Info
Full Research Paper
Published 17 Jan 2013

Calculation of the effect of tip geometry on noncontact atomic force microscopy using a qPlus sensor

  • Julian Stirling and
  • Gordon A. Shaw

Beilstein J. Nanotechnol. 2013, 4, 10–19, doi:10.3762/bjnano.4.2

Graphical Abstract
  • lateral component, raising interesting questions for both calibration and force-spectroscopy measurements. Keywords: atomic force microscopy; force spectroscopy; lateral forces; mechanical vibrations; qPlus; Introduction From imaging of individual chemical bonds [1] to subatomic resolution of the
PDF
Album
Supp Info
Full Research Paper
Published 08 Jan 2013

Current-induced forces in mesoscopic systems: A scattering-matrix approach

  • Niels Bode,
  • Silvia Viola Kusminskiy,
  • Reinhold Egger and
  • Felix von Oppen

Beilstein J. Nanotechnol. 2012, 3, 144–162, doi:10.3762/bjnano.3.15

Graphical Abstract
  • mechanical vibrations and cause limit-cycle dynamics. Keywords: current-induced forces; electronic transport theory; nanoelectromechanical systems; scattering matrix; S-matrix; Introduction Scattering theory has proved to be a highly successful method for treating coherent transport in mesoscopic systems
  • decouple, and which give rise to different experimental phenomena. On one side, when the electronic time scales are slow compared with the mechanical vibrations, drastic consequences can be observed for the electronic transport, such as side bands due to phonon-assisted tunneling [23][24] or the Frank
  • vanish even for time-reversal-symmetric conductors, since the current effectively breaks time-reversal symmetry. Current So far we have focused on the effect of the electrons on the mechanical degrees of freedom. For a complete picture, we also need to consider the reverse effect of the mechanical
PDF
Album
Supp Info
Full Research Paper
Published 20 Feb 2012

An MCBJ case study: The influence of π-conjugation on the single-molecule conductance at a solid/liquid interface

  • Wenjing Hong,
  • Hennie Valkenier,
  • Gábor Mészáros,
  • David Zsolt Manrique,
  • Artem Mishchenko,
  • Alexander Putz,
  • Pavel Moreno García,
  • Colin J. Lambert,
  • Jan C. Hummelen and
  • Thomas Wandlowski

Beilstein J. Nanotechnol. 2011, 2, 699–713, doi:10.3762/bjnano.2.76

Graphical Abstract
  • ratios ranging between 10−4 to 10−6 [54]. On the other hand, notched gold-wire samples with a typical displacement ratio of 0.01 are rather sensitive to mechanical vibrations, which could interfere with the exact horizontal adjustment of the distance between the two electrodes. As a consequence
  • voltage range of 110 V. Typically we applied a voltage between 0 and 50 V. The mechanical part of the MCBJ is positioned on a vibration-isolation breadboard (Newport RG Breadboard), which is mounted on a passive granite table to further decrease the interference from ambient mechanical vibrations and
PDF
Album
Full Research Paper
Published 18 Oct 2011
Other Beilstein-Institut Open Science Activities